Video Controlled Relay-BNC - Image 1 - Tx Vcr
SKU: TX-VCR

Video Controlled Relay-BNC

YOUR PRICE
$204.95
In Stock & Ready to Ship
Request a Quote

Professional Transparency: Shipping charges, delivery timing, and warranty coverage vary by destination and integration requirements. For bulk procurement or government pricing, please contact our specialist team.

Shipping calculated at checkout
Manufacturer warranty included
30-Day Professional Return Policy

The RDL TX-VCR is a video-controlled relay that detects the presence or loss of an NTSC or PAL video signal. It accepts a ground-referenced BNC input from 0.5 V p-p to 1 V p-p and provides a BNC loop output for insertion into a terminated video line. Its single-pole, double-throw relay supplies normally open or normally closed dry-contact outputs, while the front-panel SYNC LED indicates when valid video is detected.

Ideal Use Cases

The TX-VCR is suited to systems that require a dry-contact response based on whether a valid video signal is present. It can be used where video presence must be detected, where signal loss must be identified, or where another device needs to receive a normally open or normally closed contact state from a video source. Detection of both NTSC and PAL signals allows the relay to serve either format without requiring separate models.

Its loop-through arrangement supports installations in which the monitored signal must continue to a downstream 75 Ω load. The unit can also operate at the end of a video line when its supplied 75 Ω terminator is installed on the LOOP OUT connector.

Why Choose This Model

The TX-VCR combines signal detection, visual status indication, and relay control in a compact unit measuring 1.4 inches high, 3.0 inches long, and 1.2 inches wide. The detection circuit bridges a 1 V video line, allowing the device to monitor the signal while the loop output feeds a properly terminated load.

The SPDT relay provides both N/O and N/C contact options. This gives the installer a choice of contact behavior without requiring a different relay model. The specified maximum switching power is 60 W, with ratings listed as 220 Vdc, 125 Vac, and 2 A.

Installation and Integration

Video connects through ground-referenced BNC jacks. The input accepts video levels from 0.5 V p-p through 1 V p-p. For loop-through operation, connect the incoming source to INPUT and route LOOP OUT to a connected load terminated at 75 Ω. The LOOP OUT must be terminated either by the connected 75 Ω load or by the supplied 75 Ω terminator.

If the TX-VCR is positioned at the end of the line, install the supplied terminator on LOOP OUT. This supports terminated operation while retaining the unit’s video-detection function. The dry-contact control connection can use either the normally open or normally closed relay contact according to the required control arrangement.

Power may be supplied from a ground-referenced 12 to 33 Vdc source or a 12 to 24 Vac source. Current requirement is 75 mA. The recommended power supplies are the PS-24AS for the USA and the PS-24AX for international use; neither is included.

Performance Highlights

  • Detects the presence of valid NTSC or PAL video.
  • Detects loss of the monitored video signal.
  • Accepts 0.5 V p-p to 1 V p-p video through a ground-referenced BNC input.
  • Provides a ground-referenced BNC LOOP OUT connection.
  • Supports bridging or terminated operation.
  • Provides single-pole, double-throw N/O or N/C dry relay contacts.
  • SYNC LED illuminates while valid video is being detected.
  • Operates from either AC or DC power within the specified ranges.
  • Supports ambient operating temperatures from 0° C to 55° C.

What Makes It Different

Rather than providing only a visual indication of signal state, the TX-VCR converts video detection into an accessible relay-contact output. The combination of BNC loop-through connectivity and SPDT dry contacts allows the video path and control path to be integrated through one device. Its ability to bridge a 1 V video line or terminate the end of the line provides two documented installation configurations.

The broad power-input range also provides flexibility when integrating the unit with available ground-referenced AC or DC supplies. Valid-video status remains directly visible through the SYNC LED during operation.

Final Assessment

The RDL TX-VCR provides a focused solution for detecting NTSC or PAL video presence and loss while producing an SPDT dry-contact output. Its BNC input and loop output, supplied 75 Ω terminator, selectable N/O or N/C contacts, AC or DC power compatibility, and visible SYNC indication make its signal path and control behavior straightforward to integrate. The result is a compact video-monitoring relay with clearly defined termination, power, contact, and operating requirements.